KnowMyRig
Issue / Resolution

310RL Plumbing Guide: Gray Tank Overflow, Sewer Smell and Leaks

Michael Pardon

310RL Plumbing Guide: Gray Tank Overflow, Sewer Smell and Leaks

What 310RL owners have found behind gray tank overflows into the underbelly, sewer smells near the coffee bar, and underbelly water leaks.

Applies to: 2026 Alliance RV Paradigm 310RL, Dometic 310 Series Gravity Flush Toilet

Overview

The 310RL carries 98 gallons of fresh water, 106 gallons of gray and 53 gallons of black, per dealer spec sheets. The gray capacity is split between two tanks (see below). These are the plumbing problems owners ask about most.

How the gray tanks are set up

On our 2026 310RL, gray water goes to two separate tanks:

  • Bathroom gray tank: shower and bathroom sink
  • Kitchen gray tank: kitchen sink

On the roof you'll see two white tank vent caps; the gray tanks vent through one of them. The black cap nearby is the wire chase where roof wiring enters, not a tank vent.

310RL roof showing two white tank vent caps and a black wire chase
Roof: two white tank vent caps (the gray tanks vent through one) and the black wire chase

Because the shower shares its tank only with the bathroom sink, that tank can fill well before the combined 106 gallons is used. Watch its level during trips with long showers.

Gray tank overflowing into the underbelly

One new owner reported that on a first trip the shower's gray tank filled and water overflowed into the underbelly instead of backing up into the shower. Their dealer said this was expected. Even if it's by design, gray water in the underbelly can soak insulation and cause odors, so:

  • Dump the bathroom gray tank before it's full, especially on trips with long showers.
  • If it does overflow, dry out the underbelly and report it to Alliance as a warranty question, with photos.

Sewer smell behind the coffee bar

An owner of a 2025 310RL noticed a strong sewer smell behind the coffee bar, which backs up to the bathroom. Common sources to check:

  • A dry or failing air admittance valve under a sink
  • A P-trap that has dried out (run water down every drain after storage)
  • The toilet seal (see Fix leaking toilet)
  • A blocked or damaged roof tank vent cap

Fresh water in the underbelly

A 2021 owner found the underbelly bulging with fresh water after a long trip. Pressurize the system with the pump and check the fittings at the water panel and the manifold.

The manifold sits in the docking station (wet bay) next to the city water inlet and tank flush. On our unit it's a Flair-It manifold with every line labeled: outside shower spray port, washer prep, kitchen sink, bath 2, bathroom sink, shower, toilet and low point drain. Hot lines are marked red and cold lines blue. With the pump running, check each connection for drips. The label tells you which fixture a leaking line feeds.

Flair-It water manifold in the 310RL docking station with labeled hot and cold lines
Flair-It water manifold in the docking station, with every line labeled

Related guides

0 found helpful · 0 not helpful

Did this help? Pass it on.

Share it with your network or save it for reference later.

Still stuck? Ask about this guide